- Construction materials
-
- Inner conductor: Copper-clad aluminum wire
- Insulation: Physically foamed polyethylene
- Outer conductor: Slotted copper tape
- Jacket: LSZH flame-retardant polyolefin
- Jacket color: Black
- Construction dimensions
-
- Inner conductor diameter: 4.80 mm
- Insulation outer diameter: 12.30 mm
- Outer conductor outer diameter: 12.60 mm
- Jacket outer diameter: 15.50 mm
- Mechanical and physical properties
-
- One-time bending radius: 150 mm
- Repeated bending radius: 300 mm
- Minimum number of bends: 15
- Tensile strength: 1000 N
- Bending moment: 13.5 N·m
- Recommended clamp spacing: 0.8~1.2 m
- Minimum distance to wall: 50 mm
- Environmental performance
-
- Storage temperature: -55℃~+85℃
- Installation temperature: -40℃~+80℃
- Operating temperature: -55℃~+85℃
- Relative humidity: 95%
- RoHS:Compliant
| Electrical Performance(Basic Parameters) |
| Parameter | Value | Parameter | Value |
| Capacitance | 75.0 pF/m | Characteristic impedance | 50±2 Ω |
| Insulation resistance | ≥10000 MΩ·km | Jacket spark voltage | 8000 V |
| Velocity of propagation | 89% | Insulation test voltage | 6 kV |
| Inner conductor DC resistance | 1.65 Ω/km | Outer conductor DC resistance | 6.50 Ω/km |
| Usable frequency band | 5~2700 MHz | Optimum frequency band | 700~2700 MHz |
| Prohibited frequency band | 1110~1140 MHz、2220~2280 MHz |
| Electrical Performance - Voltage Standing Wave Ratio(VSWR) |
| Frequency band range | Max. VSWR |
| 790~960 MHz | ≤1.3 |
| 1710~2025 MHz | ≤1.3 |
| 2110~2170 MHz | ≤1.3 |
| 2300~2700 MHz | ≤1.4 |
| Electrical Performance - Attenuation and Coupling Loss(20℃) |
| Frequency(MHz) | Attenuation(dB/100m) | Coupling loss(95%,2m,dB) |
| 800 | 7.2 | 74 |
| 900 | 7.7 | 72 |
| 1800 | 11.5 | 72 |
| 1900 | 12.3 | 70 |
| 2000 | 12.8 | 70 |
| 2100 | 13.4 | 69 |
| 2200 | 14.0 | 71 |
| 2400 | 15.5 | 70 |
| 2600 | 16.8 | 70 |
| 2700 | 18.0 | 72 |
Note: Attenuation values are typical, with a maximum deviation not exceeding 5%; coupling loss tolerance is ±5 dB.
- Polarization
-
- 5~150 MHz:Cross polarization
- 700~2700 MHz:Horizontal polarization
- Test standards
-
- Flame retardancy: IEC 60332-1
- Smoke index: IEC 61034
- Toxicity index: IEC 60754-1、IEC 60754-2
- Attenuation and coupling loss: IEC 61196-4
- Certifications
-
- ISO 9001:2015:Compliant
- RoHS 2011/65/EU:Compliant
Delivery standards
- Custom production in specified lengths or cutting of existing products is supported(please specify the exact requirements in the order).
- For special protection, length or construction customization requirements, please contact our customer service to confirm.