HLCAYZ(R)-50-12C Indoor Leaky Coaxial Cable
HLCAYZ(R)-50-12C Indoor Leaky Coaxial Cable

HLCAYZ(R)-50-12C Indoor Leaky Coaxial Cable

P/N:366
Request a Quote
  • 100 Sold
Made to order — contact us to confirm stock.
    View full after-sales policy→
  • 1-Yr Replacement
  • 3-Yr Warranty
  • 25-Yr Warranty
  • Ship to
  • Free shipping · Express delivery (SF Express / Deppon available)

Product Description

Construction materials
  • Inner conductor: Copper-clad aluminum wire
  • Insulation: Physically foamed polyethylene
  • Outer conductor: Slotted copper tape
  • Jacket: LSZH flame-retardant polyolefin
  • Jacket color: Black
Construction dimensions
  • Inner conductor diameter: 4.80 mm
  • Insulation outer diameter: 12.30 mm
  • Outer conductor outer diameter: 12.60 mm
  • Jacket outer diameter: 15.50 mm
Mechanical and physical properties
  • One-time bending radius: 150 mm
  • Repeated bending radius: 300 mm
  • Minimum number of bends: 15
  • Tensile strength: 1000 N
  • Bending moment: 13.5 N·m
  • Recommended clamp spacing: 0.8~1.2 m
  • Minimum distance to wall: 50 mm
Environmental performance
  • Storage temperature: -55℃~+85℃
  • Installation temperature: -40℃~+80℃
  • Operating temperature: -55℃~+85℃
  • Relative humidity: 95%
  • RoHS:Compliant
Electrical Performance(Basic Parameters)
Parameter Value Parameter Value
Capacitance 75.0 pF/m Characteristic impedance 50±2 Ω
Insulation resistance ≥10000 MΩ·km Jacket spark voltage 8000 V
Velocity of propagation 89% Insulation test voltage 6 kV
Inner conductor DC resistance 1.65 Ω/km Outer conductor DC resistance 6.50 Ω/km
Usable frequency band 5~2700 MHz Optimum frequency band 700~2700 MHz
Prohibited frequency band 1110~1140 MHz、2220~2280 MHz
Electrical Performance - Voltage Standing Wave Ratio(VSWR)
Frequency band range Max. VSWR
790~960 MHz ≤1.3
1710~2025 MHz ≤1.3
2110~2170 MHz ≤1.3
2300~2700 MHz ≤1.4
Electrical Performance - Attenuation and Coupling Loss(20℃)
Frequency(MHz) Attenuation(dB/100m) Coupling loss(95%,2m,dB)
800 7.2 74
900 7.7 72
1800 11.5 72
1900 12.3 70
2000 12.8 70
2100 13.4 69
2200 14.0 71
2400 15.5 70
2600 16.8 70
2700 18.0 72

Note: Attenuation values are typical, with a maximum deviation not exceeding 5%; coupling loss tolerance is ±5 dB.

Polarization
  • 5~150 MHz:Cross polarization
  • 700~2700 MHz:Horizontal polarization
Test standards
  • Flame retardancy: IEC 60332-1
  • Smoke index: IEC 61034
  • Toxicity index: IEC 60754-1、IEC 60754-2
  • Attenuation and coupling loss: IEC 61196-4
Certifications
  • ISO 9001:2015:Compliant
  • RoHS 2011/65/EU:Compliant

Delivery standards

  • Custom production in specified lengths or cutting of existing products is supported(please specify the exact requirements in the order).
  • For special protection, length or construction customization requirements, please contact our customer service to confirm.
Request a Quote