- Construction Dimensions
-
- Inner conductor diameter: 3.60 mm
- Insulation outer diameter: 9.10 mm
- Outer conductor outer diameter: 12.00 mm
- Jacket outer diameter: 13.30 mm
- Construction Materials
-
- Inner conductor: copper-clad aluminum
- Insulation: physically foamed polyethylene
- Outer conductor: spiral corrugated copper tube
- Jacket: low smoke zero halogen flame-retardant polyolefin
- Jacket color: black
- Mechanical and Physical Properties
-
- Single bend radius: 15 mm
- Repeated bend radius: 30 mm
- Minimum number of bends: 15
- Tensile strength: 650 N
- Crush resistance: 19 N/mm
- Environmental Performance
-
- Storage temperature: -55℃~+85℃
- Installation temperature: -40℃~+60℃
- Operating temperature: -55℃~+85℃
| Electrical Performance (Basic Parameters) |
| Parameter | Value | Parameter | Value |
| Capacitance | 80.0 pF/m | Characteristic Impedance | 50±1 Ω |
| Velocity of Propagation | 82% | Insulation Resistance | 10000 MΩ·km |
| Jacket Spark Voltage | 5000 V | RF Peak Voltage | 1.13 kV |
| Peak Power | 12 kW | Cut-off Frequency | 12.50 GHz |
| Shielding Effectiveness (>10MHz) | >120 dB |
| Electrical Performance - Return Loss/VSWR |
| Frequency Range | Return Loss | VSWR Max | Remarks |
| 0.8~1.0 GHz | 26.4 dB | 1.10 | Low band |
| 1.7~2.2 GHz | 24.3 dB | 1.13 | Mid band |
| 2.2~2.7 GHz | 23.1 dB | 1.15 | Mid-high band |
| 3.3~3.6 GHz / 4.8~5.0 GHz | 20.8 dB | 1.20 | High band |
| Electrical Performance - Attenuation and Average Power (20℃) |
| Frequency (MHz) | Attenuation (dB/100m) | Average Power (kW) |
| 100 | 3.13 | 3.03 |
| 150 | 3.93 | 2.39 |
| 200 | 4.51 | 2.11 |
| 280 | 5.49 | 1.69 |
| 450 | 6.99 | 1.37 |
| 800 | 9.57 | 1.00 |
| 900 | 10.25 | 0.94 |
| 1000 | 10.83 | 0.88 |
| 1500 | 13.40 | 0.70 |
| 1800 | 15.10 | 0.63 |
| 2000 | 15.92 | 0.59 |
| 2200 | 16.84 | 0.59 |
| 2400 | 17.57 | 0.53 |
| 2500 | 17.96 | 0.52 |
| 3000 | 20.29 | 0.48 |
| 3300 | 21.11 | 0.46 |
| 3600 | 22.19 | 0.43 |
| 4000 | 23.60 | 0.41 |
| 4500 | 25.29 | 0.38 |
| 4800 | 26.27 | 0.37 |
| 5000 | 26.91 | 0.36 |
Note: The above attenuation and average power values are typical values with a maximum deviation of no more than 5%.
- Certifications
-
- ISO 9001:2015: Compliant
- RoHS 2011/65/EU: Compliant
Delivery Standards
- Custom production to specified lengths or cutting of existing products available (please specify detailed requirements in the order).
- For special protection, length or structural customization requirements, please contact customer service for further confirmation.