- Construction Dimensions
-
- Inner conductor diameter: 1.90 mm
- Insulation outer diameter: 4.75 mm
- Outer conductor outer diameter: 6.35 mm
- Jacket outer diameter: 7.50 mm
- Construction Materials
-
- Inner conductor: copper-clad aluminum
- Insulation: physically foamed polyethylene
- Outer conductor: spiral corrugated copper tube
- Jacket: low smoke zero halogen flame-retardant polyolefin
- Jacket color: black
- Mechanical and Physical Properties
-
- Single bend radius: 12.5 mm
- Repeated bend radius: 25 mm
- Minimum number of bends: 15
- Tensile strength: 600 N
- Crush resistance: 18 N/mm
- Environmental Performance
-
- Storage temperature: -55℃~+85℃
- Installation temperature: -40℃~+60℃
- Operating temperature: -55℃~+85℃
| Electrical Performance (Basic Parameters) |
| Parameter | Value | Parameter | Value |
| Capacitance | 80.0 pF/m | Characteristic Impedance | 50±1 Ω |
| Velocity of Propagation | 83% | Insulation Resistance | 5000 MΩ·km |
| Jacket Spark Voltage | 3000 V | RF Peak Voltage | 0.80 kV |
| Peak Power | 6.40 kW | Cut-off Frequency | 20.40 GHz |
| Shielding Effectiveness (>10MHz) | >120 dB |
| Electrical Performance - Return Loss/VSWR |
| Frequency Range | Return Loss | VSWR Max | Remarks |
| 0.8~1.0 GHz | 26.4 dB | 1.10 | Low band |
| 1.7~2.2 GHz | 24.3 dB | 1.13 | Mid band |
| 2.2~2.7 GHz | 23.1 dB | 1.15 | Mid-high band |
| 3.3~3.6 GHz / 4.8~5.0 GHz | 20.8 dB | 1.20 | High band |
| Electrical Performance - Attenuation and Average Power (20℃) |
| Frequency (MHz) | Attenuation (dB/100m) | Average Power (kW) |
| 100 | 5.60 | 1.23 |
| 150 | 7.25 | 0.95 |
| 200 | 8.00 | 0.86 |
| 280 | 10.20 | 0.67 |
| 450 | 12.20 | 0.57 |
| 800 | 16.70 | 0.42 |
| 900 | 17.50 | 0.39 |
| 1000 | 18.60 | 0.37 |
| 1500 | 23.40 | 0.30 |
| 1800 | 25.70 | 0.27 |
| 2000 | 26.90 | 0.26 |
| 2200 | 28.50 | 0.25 |
| 2400 | 30.00 | 0.24 |
| 2500 | 30.60 | 0.23 |
| 3000 | 33.50 | 0.21 |
| 3300 | 35.02 | 0.19 |
| 3600 | 36.73 | 0.18 |
| 4000 | 38.92 | 0.17 |
| 4500 | 41.53 | 0.16 |
| 4800 | 43.05 | 0.15 |
| 5000 | 44.03 | 0.15 |
Note: The above attenuation and average power values are typical values with a maximum deviation of no more than 5%.
- Certifications
-
- ISO 9001:2015: Compliant
- RoHS 2011/65/EU: Compliant
Delivery Standards
- Custom production to specified lengths or cutting of existing products available (please specify detailed requirements in the order).
- For special protection, length or structural customization requirements, please contact customer service for further confirmation.